Filters Options |
---|
❮
❯
1. 2†MERV8 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
*Pictures shows entering air side to filters
MIXED AIR FILTERS 2†+ 4†FILTERS
1 / 4
Mixed air filters come standard with a 2†MERV8 +4†Merv13 filters. The 2†captures large particles and are inexpensive to replace. The 4†MERV13 provide higher filtration suitable for commercial buildings and are moderate in price. The full cabinet filters reduce bypass air at the mixed air filters.1. 2†MERV8 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
*Pictures shows entering air side to filters
❮
❯
1. 2†MERV8 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
3. Front Load Filter Track
2
1 / 4
Closeup view of the 2†MERV8 + Merv 13 Filters. These are front loaded filters for ease of maintenance.
These (2) filters may also be 2" MERV4 + 4" MERV13 or any combination of available MERV Ratings1. 2†MERV8 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
3. Front Load Filter Track
❮
❯
FEATURES
1. 2†MERV4 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
3. Filter Pressure Drop Transducer
*4†filters behind 2†MERV4 Filter
Merv4 + MERV13 Filters Bank
1 / 4
This filter bank exhibits the filter drop pressure transducer that monitors the pressure drop caused by dirty filters. The pressure drop set point can be set to annunciate a remote alarm indicating time to replace the dirty filters.FEATURES
1. 2†MERV4 + 4†MERV13 Pleated Filters
2. Fully Housed Filter Rack
3. Filter Pressure Drop Transducer
*4†filters behind 2†MERV4 Filter
❮
❯
1. Communicating Pressure Transducer
Filter Pressure Gauage
1 / 4
The pressure transducer is a communication device that communicates to the unit’s microprocessor controller. The transducer measures the pressure drop in the common measure of “Inches of Water Gaugeâ€. This pressure drop can then be transmitted to the building automation system and a “Filter Alarm†can be sent by text, email or computer to let the facility know it is time to change the dirty filters. 1. Communicating Pressure Transducer
❮
❯
1. 12†MERV15 Pleated Final Filters
2. Fully Housed Filter Rack
*Entering air side of filters
FinalFilter Section
1 / 4
The Final Filter Section is the last device in the airstream and insure complete filtration of microbial contaminants before the air enters the building. MERV ratings can be selected according to need from MERV15-MERV20. View the MERV Rating Chart for complete description of MERV Rating applications and Arrestance particle size.1. 12†MERV15 Pleated Final Filters
2. Fully Housed Filter Rack
*Entering air side of filters
❮
❯
1. 12†MERV15 Pleated Final Filters
2. Fully Housed Filter Rack
*Leaving air side of filters
Final FIlters - Leaving Air Side
1 / 4
This picture shows the leaving side of the filter bank. These 12†final filter provide the best filtration possible. Filter ratings can be provided to equal surgery rooms if desired which would have a 99.99% Arrestance Rate (MERV20). Refer to the MERV Rating Chart for complete description of MERV Rating applications and arrestance particle size.1. 12†MERV15 Pleated Final Filters
2. Fully Housed Filter Rack
*Leaving air side of filters
❮
❯
1. Washable Aluminum Filter Racks
Outside Air Hood w/ Filters
1 / 4
Each Outside Air Hood is provided with a set of washable aluminum filters to pre-treat the outside air and filter alrge debris from the air stream.1. Washable Aluminum Filter Racks
Categories
- Cabinet Features (9)
- Compressors and Refrigeration Circuits (17)
- Controls and Power Section (4)
- Fan Options (0)
- Filters Options (9)
- Coils (0)
- Outside air Dampers and Hoods (7)
- Supply and Exhaust Fan Options (0)
- Air Discharge Opening Options (0)